  1. ______________________________________________________________________________ 
  2.  
  3. The first thing to do is make a BACKUP copy of PMB and put it away. This is 
  4. good advise and you should do this with ANY pgm you aquire. 
  5.  
  6. UNARC PMB.ARC on a blank formated disk that does NOT contain your System files
  7. on it as you will need all the room available, after the file is UNARCED 
  8. delete the PMB.ARC file from the disk. 
  9.  
  10. FOR HIGH VOLUME DISKETTES: 
  11. Transfer ALL these files on a disk containing your System Operating Files 
  12. and type: <RUN1ST>  this will create the necessary Sub-directorys and place
  13. the various files where they belong. ALWAYS start PMB from the ROOT directory.
  14. Type RUN to start PMB. 
  15.   
  16. FOR 360K DISKETTES: 
  17. If using a 5 1/4" diskette then format a disk without the systems files and 
  18. then copy ALL the files from the PMB disk to this newly formatted disk, then
  19. after running RUN1ST.BAT copy your COMMAND.COM to the ROOT directory of the  
  20. diskette.  Type  RUN  to start PMB. 
  21. ______________________________________________________________________________ 
  22.  
  23. NOTICE!!!  To INSTALL the pgms on this disk to your Hard drive put this disk 
  24. in the (A) drive and type   INSTALL 
  25. ______________________________________________________________________________ 
  26.  
  27. All the files that end in .SET are in the \PMB\MB directory and contain the 
  28. parameter settings for the TNC.  
  29.  
  30. TNCPARMS.SET ----- sets the overall TNC parameters. 
  31.  
  32. The 2 BAUD.SET files set the TNC and  PMB's baud rate (TNC to computer). 
  33.  
  34. NOTE!!!  If you are using an AEA TNC then change the last line in both   
  35. of the BAUD.SET files from RESET to RESTART or whatever the command is that 
  36. you use to change the TNC to computer baud rate and the first line to whatever
  37. is used to change the baud rate, (TNC to computer baud rate). 
  38.  
  39. Example of what the BAUD.SET files should look like: 
  40.  
  41.       ( AEA )            ( KANTRONICS ) 
  42.  
  43.      TBAUD 1200             ABAUD 1200 
  44.      RESTART                RESET 
  45.  
  46. The complete DOCUMENTATION file is contained in the PMB directory which you 
  47. can read by pressing F5 and then follow the prompts in the menu. 
  48.  
  49. ALL files must be in the proper sub-directorys in order to run PMB. If a file 
  50. is missing or in the wrong place PMB will tell you so when you attempt to  
  51. run the pgm or certain functions of the pgm. 
  52.  
  53. Use the EDITOR to edit the TNCPARMS.SET file to accomidate your brand of TNC. 
  54. This file may be found in the \PMB\MB directory. DO NOT DELETE ANY PARAMETERES 
  55. THAT ARE THERE, YOU CAN ADD NEW ONES HOWEVER!!! 
  56. ______________________________________________________________________________ 
  57.  
  58. If you are using the PK-232, delete TNCPARMS.SET file and rename PK-232.SET  
  59. to TNCPARMS.SET. 
  60. ______________________________________________________________________________ 
  61.  